[ratings]Material Safety Data Sheet (MSDS) of LiPoly Battery is the battery manufacturer showing the chemistry characters. It’s a document that may pose a hazard to the user’s health such as carcinogenic, teratogenic, etc.
MSDS of PRODUCT IDENTIFIER:
LiPoly Battery
APPROVED USE OF THE CHEMICAL AND RESTRICTIONS:
Portable Electronic Equipments
MSDS RECOMMENDED AGAINST:
1.1 Do not dismantle, open or shred lipoly batteries or cells.
1.2 Do not expose lipoly batteries or cells to heat or fire. Avoid storage in direct sunlight.
1.3 Do not short-circuit a lipoly battery or a cell.
1.4 Do not store lipoly batteries or cells haphazardly in a box or drawer where they may short-circuit each other or short-circuit by other metal objects.
1.5 Do not remove a lipoly battery or a cell from its original packaging until required for use.
1.6 Do not subject lipoly batteries or cells to mechanical shock.
1.7 In the event of a lipoly battery or a cell leaking, do not allow the liquid to come in contact with the skin or eyes. If the contacts have been made, wash the affected area with copious amounts of water and seek medical advice.
1.8 Do not use any other charger than that expressly provided for use with the equipment.
1.9 Observe the plus(+) and minus(-) marks on the lipoly battery or the cell equipment and ensure correct use.
1.10 Do not use any lipoly battery or cell which is not designed for use with equipment.
1.11 Do not mix lithium polymer batteries or cells of different manufacturers, capacity, size or type within a device.
1.12 Battery usage by children should be supervised.
1.13 Seek medical advice immediately if a lipoly battery or a cell has been swallowed.
1.14 Always purchase the lipoly battery or the cell recommend by the device manufacturer for the equipment.
1.15 Keep the lipoly batteries or the cells clean and dry.
1.16 Wipe the lipoly battery or the cell terminals with a clean, dry cloth if they become dirty.
1.17 The lipoly batteries or the cells need to be charged before use. Always use the original & correct charger and refer to the manufacturer’s instructions or equipment manual for proper charging instructions.
1.18 Do not leave a lipoly battery or a cell on prolonged charge when not in use.
1.19 After extended periods of storage, it may be necessary to charge and discharge the lipoly batteries or the cells several times to obtain maximum performance.
1.20 Retain the original product literature for future reference.
1.21 Use only the lipoly battery or the cell in the application for which it was intended.
1.22 When possible, remove the lipoly battery or the cell from the equipment when not in use.
1.23 Dispose of properly.
2.3 GHS Label elements, including precautionary statements
Signal word: Warning
Hazard statements:
H242: Heating may cause a fire
H311: Toxic in contact with the skin
H314: Causes severe skin burns and eye damage
H302: Harmful if swallowed
2.4 Precautionary statements
Restriction:
P264 Wash thoroughly after handing.
P270 Do not eat, drink or smoke when using this product.
P280 Wear protective gloves / protective clothing / eye protection / face protection
Compliance:
P312: Call a poison center or doctor/physician if you feel unwell.
P302+P350 IF ON SKIN: Gently wash with plenty of soap and water.
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do not induce vomiting.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Disposal:
P501: Dispose of contents/container by local/national regulations

3. CONSTRUCTION / INFORMATION ON INGREDIENTS OF MSDS
Chemical characterization: Mixtures
Description:
Product: Consisting of the following components.
Note: CAS number is Chemical Abstract Service Registry Number.

4. FIRE-AID FIGHTING MEASURES
4.1 Suitable Extinguishing Media
CO2, dry chemical powder, water spray.
4.2 Specific Hazards Arising from the Chemical
Formation of toxic gases is possible during heating or in case of fire.
In case of fire, the following can be released:
Carbon monoxide(CO)
Carbon dioxide
Other irritating and toxic gases.
4.3 Hazardous Combustion LiPoly Battery
Carbon oxides
Explosion Data
Sensitivity to Mechanical Impact: No
Sensitivity to Static Discharge: No
4.4 Protective Devices and Forethoughts for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. For example: Wear self-contained respiratory protective device. Wear suitable protective clothing and eye/face protection.
4.5 Special hazards arising from the substance or mixture:
LiPoly Battery may burst and release hazards decomposition products when exposed to a fire situation. lipoly battery contains the flammable electrolyte that may vent, ignite and produce sparks when subjected to high temperature(>150°C), When damaged or abused(e.g. mechanical damage or electrical overcharging); may burn rapidly with flare-burning effect; may ignite other batteries in clothes proximity.
5. NONESSENTIAL RELEASE MEASURES
5.1 Personal precautions, protective equipment, and emergency procedures
Personal Precautions avoid contact with eyes. Refer to section 8 for personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas.
5.2 Environmental forethoughts
Absorb with the liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
5.3 Methods and material for containment and cleaning up
Methods for containment Prevent further leakage or spillage if safe to do so.
Methods for cleaning up: Use personal protective equipment. Dam up. Cover liquid spill with sand, earth or other Noncombustible absorbent material. Pick up and transfer to properly labeled containers. Clean contaminated surface thoroughly.
6. FIRST-AID MEASURES
6.1 First aid measures
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. If symptoms persist, call a physician. Skin Contact Remove contaminated clothing and shoes. Wash skin with soap and water. In the case of skin irritation or allergic reactions see a physician. Inhalation: Move to fresh air. If symptoms persist, call a physician. Ingestion: Do NOT induce vomiting. Drink plenty of water. If symptoms persist, call a physician.
6.2 Most important symptoms and effects, both acute and delayed. Swallowing Do not induce vomiting. Get medical attention.
7. HANDLING AND STORAGE
7.1 Forethoughts for safe handling
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes, and clothing. Wear personal protective equipment. Wash thoroughly after handling. Use this material with adequate ventilation. The lipoly battery is not explosive.
7.2 Conditions for safe storage, including any incompatibilities
If the LiPoly Battery is subject to storage for such a long term as more than 3 months, it is recommended to recharge the LiPoly Battery periodically.
3 months: -10°C~ +40°C, 45 to 85%RH.
And recommended at 0°C~ +35°C for long period storage.
The capacity recovery rate in the delivery state (50% capacity of fully charged) after storage is assumed to be 80% or more.
The voltage for a long time storage shall be 3.8V ~ 4.8V range.
Do not storage LiPoly Battery haphazardly in a box or drawer where they may short-circuit each other or be short-circuited by other metal objects.
Keep out of reach of children.
Do not expose LiPoly Battery to heat or fire. Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic materials.
Keep ignition sources away – Do not smoke.
Store in cool, dry and well-ventilated place.
8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
8.1 Instrument Parameters
Ingredients with limit values that require monitoring at the workplace
12190-79-3 Lithium Cobalt Oxide
TLV (USA): 0.02mg/m3
MAK (Germany): 0.1mg/m3
Vacated limits revoked by the court of appeals decision in AFL-CIO OSHS 965 F.2d 962 (11th Cir., 1992)
8.2 Individual protection measures, such as personal protective equipment
Eye/Face Protection
Body protection
Skin protection
Respiratory Protection
Hygiene Measures

4. FIRE-AID FIGHTING MEASURES
4.1 Suitable Extinguishing Media
CO2, dry chemical powder, water spray.
4.2 Specific Hazards Arising from the Chemical
Formation of toxic gases is possible during heating or in case of fire.
In case of fire, the following can be released:
Carbon monoxide(CO)
Carbon dioxide
Other irritating and toxic gases.
4.3 Hazardous Combustion LiPoly Battery
Carbon oxides
Explosion Data
Sensitivity to Mechanical Impact: No
Sensitivity to Static Discharge: No
4.4 Protective Devices and Forethoughts for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. For example: Wear self-contained respiratory protective device. Wear suitable protective clothing and eye/face protection.
4.5 Special hazards arising from the substance or mixture:
LiPoly Battery may burst and release hazards decomposition products when exposed to a fire situation. lipoly battery contains the flammable electrolyte that may vent, ignite and produce sparks when subjected to high temperature(>150°C), When damaged or abused(e.g. mechanical damage or electrical overcharging); may burn rapidly with flare-burning effect; may ignite other batteries in clothes proximity.
5. NONESSENTIAL RELEASE MEASURES
5.1 Personal precautions, protective equipment, and emergency procedures
Personal Precautions avoid contact with eyes. Refer to section 8 for personal protective equipment. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas.
5.2 Environmental forethoughts
Absorb with the liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
5.3 Methods and material for containment and cleaning up
Methods for containment Prevent further leakage or spillage if safe to do so.
Methods for cleaning up: Use personal protective equipment. Dam up. Cover liquid spill with sand, earth or other Noncombustible absorbent material. Pick up and transfer to properly labeled containers. Clean contaminated surface thoroughly.
6. FIRST-AID MEASURES
6.1 First aid measures
Eye Contact Rinse thoroughly with plenty of water, also under the eyelids. If symptoms persist, call a physician. Skin Contact Remove contaminated clothing and shoes. Wash skin with soap and water. In the case of skin irritation or allergic reactions see a physician. Inhalation: Move to fresh air. If symptoms persist, call a physician. Ingestion: Do NOT induce vomiting. Drink plenty of water. If symptoms persist, call a physician.
6.2 Most important symptoms and effects, both acute and delayed. Swallowing Do not induce vomiting. Get medical attention.
7. HANDLING AND STORAGE
7.1 Forethoughts for safe handling
Handle in accordance with good industrial hygiene and safety practice. Avoid contact with skin, eyes, and clothing. Wear personal protective equipment. Wash thoroughly after handling. Use this material with adequate ventilation. The lipoly battery is not explosive.
7.2 Conditions for safe storage, including any incompatibilities
If the LiPoly Battery is subject to storage for such a long term as more than 3 months, it is recommended to recharge the LiPoly Battery periodically.
3 months: -10°C~ +40°C, 45 to 85%RH.
And recommended at 0°C~ +35°C for long period storage.
The capacity recovery rate in the delivery state (50% capacity of fully charged) after storage is assumed to be 80% or more.
The voltage for a long time storage shall be 3.8V ~ 4.8V range.
Do not storage LiPoly Battery haphazardly in a box or drawer where they may short-circuit each other or be short-circuited by other metal objects.
Keep out of reach of children.
Do not expose LiPoly Battery to heat or fire. Avoid storage in direct sunlight.
Do not store together with oxidizing and acidic materials.
Keep ignition sources away – Do not smoke.
Store in cool, dry and well-ventilated place.
8. EXPOSURE CONTROLS AND PERSONAL PROTECTION
8.1 Instrument Parameters
Ingredients with limit values that require monitoring at the workplace
12190-79-3 Lithium Cobalt Oxide
TLV (USA): 0.02mg/m3
MAK (Germany): 0.1mg/m3
Vacated limits revoked by the court of appeals decision in AFL-CIO OSHS 965 F.2d 962 (11th Cir., 1992)
8.2 Individual protection measures, such as personal protective equipment
Eye/Face Protection
Body protection
Skin protection
Respiratory Protection
Hygiene Measures

9. STABILITY AND REACTIVITY
9.1 Reactivity
Stable under recommended storage and handling conditions.
9.2 Element stability
Stable under normal conditions of use, storage, and transport.
9.3 Thermal decomposition/conditions to be avoided
No decomposition if used according to specifications.
9.4 The possibility of Hazardous Reactions
None under normal processing.
9.5 Hazardous Polymerization
Hazardous polymerization does not occur.
9.6 Conditions to avoid
Strong heating, fire, Incompatible materials
9.7 Incompatible materials
Strong oxidizing agents. Strong acids. Base metals.
9.8 Hazardous Decomposition Products
Carbon oxides, other irritating and toxic gases.
10. DISPOSAL CONSIDERATIONS
10.1 Waste treatment methods
Recommendation: Must not be disposed of together with household garbage. Do not allow the product to reach the sewage system
10.2 Uncleaned packaging:
Recommendation: Disposal must be made according to official regulations.
11 TRANSPORT INFORMATION
11.1 The LiPoly Battery had been tested according to the requirements of the UN manual of tests and Criteria.
11.2 The LiPoly Battery with a Watt-hour rating not exceeding 100Wh or the cell with a Watt-hour rating in not exceeding of 20Wh.
11.3 Meets the requirements of International Maritime Dangerous Goods(IMDG)-2014 Special Provision 188 to be transported as non-dangerous goods;
11.4 Meets the requirements of 49CFR173.185 to be transported as non-dangerous goods for the road, rail, air, and vessel.
11.5 Meets the requirements of TDG special provision 34 to be transported as non-dangerous goods.
11.6 The package must be handled with care and that a flammability hazard exists if the package is damaged.
11.7 The packaging shall be adequate to avoid mechanical damage during transport, handling and stacking. The materials and pack design shall be chosen so as to prevent the development of unintentional electrical conduction, corrosion of the terminals and ingress of moisture.
12. PHYSICAL AND CHEMICAL PROPERTIES
13. REGULATORY INFORMATION
13.1 Safety, health and environmental regulations/legislation specific to the substance or mixture
13.2 Regulatory information
Mobile Phone Battery & Car Battery
Mobile Phone Battery & Car Battery The current lithium Ion battery is used for two fields. One is electric car, the other one is 3C products. 3C products are kinds of household appliances. The most extensive needs of the lithium ion battery are mobile phone...
Flexible Lithium Battery Technology
Flexible Lithium Battery Technology More and more products have become flexible, and as an essential accessory, the lithium battery also needs to be flexible. We never stop improving the technology and production process on our flexible lithium battery from design to...
What’s the graphene battery?
What's the graphene battery? Graphene Battery is a new development prospect of lithium battery which we keep paying more attention to the technology of graphene battery. The advantages of graphene in lithium batteries Graphene plays a role in enhancing the heat...
UL1642 Certification for Lithium-ion Battery
UL1642 Certification UL1642 Certification for Lithium Ion Battery | All items in the test report of UL1642Introduction of UL1642 CertificationConstruction of UL1642 CertificationPerformance of UL1642 CertificationTests of UL2054 CertificationFire Exposure...
LiPoly Battery Quality Control
LiPoly Battery Quality Control[ratings] Material of LiPoly Battery | Coating of LiPoly Battery | Sheeting of LiPoly Battery | Wrapping of LiPoly Battery | Baking of LiPoly Battery | Aging & Grading of LiPoly Battery | Assembling of LiPoly Battery | Packing of...
LiPoly Battery IEC62133-2-2017
LiPoly Battery IEC62133-2-2017[ratings] IEC62133-2:2017 is the most well-known standard for exporting lipoly battery, including those used in IT Equipment, GPS, wearable products, smartwatch, Bluetooth devices, wireless sensors, tools, laboratory, household and...
How to Store LiPoly Battery Safely
How to Store LiPoly Battery Safely The Temperature of LiPoly Battery | The Humidity of LiPoly Battery | Charge Rate & Discharge of LiPoly Battery You should keep lipoly battery in temperature -20° C to 35°C with low humidity and no corrosive gas to keep the...
LiPoly Battery Performance Standards
LiPoly Battery Performance Standards LiPoly Battery Standard Charge/Discharge Conditions | LiPoly Battery Cycle Life Test Standard | LiPoly Battery Short Circuit Test Standard | LiPoly Battery Abnormal Charging Test Standard | LiPoly Battery Thermal Shock Test...
LiPoly Battery UN38.3
LiPoly Battery UN38.3 What's lipoly battery UN38.3? LiPoly Battery UN38.3 Test Items? LiPoly Battery Altitude Simulation | LiPoly Battery Temperature Test | LiPoly Battery Oscillation | LiPoly Battery Collision | LiPoly Battery External Short Circuit | LiPoly Battery...
Common Problems and Analysis of LiPoly Battery
Common Problems and Analysis of LiPoly Battery Pack Why doesn't the lipoly battery pack be recharged? Why doesn't the lipoly battery pack work? Why isn't the lipoly battery pack fully charged? Why is the lipoly battery working time shorter than before? Why is the...